GENERATOR SPECIFICATIONS

400 Hz 115/200 volts nominal, +/- 15% adjustable, 3 phases, 4 wire wye-connected, grounded neutral, revolving field, brushless, self-cooling, single bearing, brushless rotating rectifier assembly, directly connected to the engine.

ENGINE SPECIFICATIONS

- 24 volt starting motor - Dry-type air cleaner

- Heavy-duty spark - (2) 12-volt batteries arrestor / silencer

- Full flow fuel filter

- Pusher type fan - De-aerator tank

- Full-flow lubricating oil filter

- Low coolant shutdown

GENERATOR CONTROLS

Digital generator control module (GCM) features voltage regulation, generator fault protection, and a generator operating parameter display. The GCM monitors the 400 Hz output when 400 Hz is in use and automatically switches over to monitor 28.5 VDC output when optional 28.5 VDC transformer rectifier is in use. The voltage regulator provides line drop compensation on 400 Hz as well as line drop compensation and current limiting on optional 28.5 VDC transformer rectifier. The GCM displays the generator output operating parameters such as voltage, current, and frequency digitally on a backlit LCD. The GCM is programmed to provide generator output fault protection in the following settings:

- Over frequency: 420 Hz in 5 seconds

- Under frequency: 380 Hz in 7 seconds

- Over voltage: 130 volts in 2 seconds

- Under voltage: 100 volts in 7 seconds

- Overload: 125% of rated load for 5 minutes

The GCM displays and latches the fault if any of the above should occur.

ENGINE CONTROLS

On electronic diesel engine versions, the electronic engine governors provide precise frequency regulation and fast transient response. Engine protection such as low oil pressure, high coolant temperature, and over speed

protection are programmed into the engine electronic control module. An engine diagnostic connector is

provided for communicating with the engine. Engine operating parameters are displayed with electronic gauges via SAE J1939 Controller Area Network, which include:

- Engine hours

- Engine RPM

- System Voltage

- Oil Pressure

- Coolant temperature

- % Engine load at the current RPM

- Active and stored service codes

- View engine configuration parameters

A separate analog fuel gauge is provided.

Automatic engine cool down and emergency shutdown are standard engine controls.

ELECTRICAL CHARACTERISTICS

- Voltage regulation: +/- 1% maximum over full range of generator loading.

- Voltage transient: +/- 13.8% no load to full load.

- Voltage transient recovery time: +/- 1% of nominal Voltage within 100 milliseconds.

- Voltage modulation: 0.5% at steady state.

- Phase balance:

Not to exceed 1% at balanced 3-phase load.

Not to exceed 4% at 1/3 load on 1 phase and no-load on the other 2 phases.

- Harmonic content: Total harmonic distortion not to exceed 2%. Any single phase harmonic not to exceed 1.5% at 0.8 P.F. linear load.

- Crest factor: 1.414 +/- 0.07

- Frequency regulation: +/- 0.1% no-load to full-load and overload.

Begär ett leasingerbjudande

Denna återförsäljare accepterar endast leasingförfrågningar från Tyskland. Så ange ett tyskt telefonnummer. Det är inte möjligt att ange ett nummer som är registrerat i ett annat land.

Administratören av personuppgifter som behandlas i ovanstående formulär är TRUCK1 sp. z o.o. med sitt registrerade kontor på ul. Aleje Jerozolimskie 85/21, 02-001 Warszawa, NIP: 7011085742, REGON: 521876921. E-postkontakt: info@truck1.eu. Personuppgifter behandlas i syfte att hantera förfrågan som skickas via det angivna formuläret enligt art. 6 sek. 1 bokstav f i GDPR. Varje användare har rätt att begära tillgång till sina personuppgifter, rättelse, radering (i motiverade fall), begränsning av behandling och invändning mot behandling, samt rätt att lämna in ett klagomål till Tillsynsmyndigheten för Dataskydd. Mer information om behandlingen av personuppgifter finns i informationsklausulerna som publiceras på webbplatsen: Integritetspolicy.

Genom att klicka på någon länk på denna sida bekräftar du ditt samtycke och tillstånd att behandla dina personuppgifter, inklusive användningen av cookies och annan spårningsteknik. Det är implementerat för att förbättra och personifiera din erfarenhet på denna webbplats, andra våra webbplatser och webbplatser för tredjepartsannonsörer som samarbetar med oss. Våra partners kan också lagra cookies på din enhet eller använda liknande teknik för att samla in och behandla personuppgifterna. Läs mer om hur vi behandlar dina personuppgifter.
t1 old test unit
t1 test unit - leasing - Ground support equipment
t1 test unit - leasing - Air Business GSE